How to use the balance

Analytical balances are essential tools in quantitative analysis, playing a crucial role in ensuring accurate and reliable results. A thorough understanding of the instrument’s performance and proper handling techniques are vital for achieving precision. Among various types of analytical balances—such as standard mechanical balances, semi-automatic or automatic electro-optical projection damping balances, and electronic analytical balances—the latter is widely used due to its high accuracy and ease of use. Below is a detailed guide on how to operate an electronic analytical balance and important safety precautions to keep in mind. Before starting, ensure that the balance is placed on a level surface. Adjust the leveling feet if necessary to maintain stability. Next, check the power supply voltage and make sure it matches the balance's requirements. If needed, use a voltage stabilizer to prevent fluctuations. Allow the balance to warm up for the recommended time before use, as this helps stabilize internal components and ensures accurate readings. Once the balance has warmed up, turn it on. The device will automatically calibrate itself by adjusting sensitivity and zero point. Wait until the stability indicator appears on the display before beginning the weighing process. When performing the weighing, place a clean weighing bottle or paper on the pan, close the side door, and press the tare button gently. This will reset the display to zero. Then, carefully add the sample until the desired weight is reached, indicated by the “→” symbol on the screen. After completing the measurement, remove the sample promptly, close the side door, and turn off the power. It’s also important to record the usage in the logbook for traceability and maintenance purposes. **Precautions:** 1. Always place the balance on a solid, stable surface such as a concrete or wooden table. Avoid areas with vibrations or temperature fluctuations. Keep the room clean, dry, and at a constant temperature. Direct light should be avoided to prevent interference with readings. 2. When weighing, open the side door to add or remove samples. Close the door while reading to prevent air currents from affecting the balance. The front door should only be opened during maintenance or when cleaning residual materials. 3. If the balance is not used for an extended period, it’s advisable to power it on once a week and let it warm up for two hours. This helps maintain its performance and prevents long-term damage. 4. Place a desiccant, like silica gel, inside the balance chamber to absorb moisture. Replace or bake the desiccant when it changes color to maintain a dry environment. 5. For volatile, corrosive, acidic, or alkaline substances, always use a covered weighing container to prevent contamination or damage to the balance. By following these steps and precautions, you can ensure the longevity and accuracy of your electronic analytical balance, making it a reliable tool in any laboratory setting.

Kitchenware

Silicone Kitchenware Set,Stainless Steel Tableware,Pvc Beer Bottle Opener,Camellia Colored Glass Bowl

Huayao Master (Puyang) Automation Equipment Co., Ltd. , https://www.huayaomaster.com

Posted on